Free AGA-3 6.3 Download
Current Page: Home > Business > Vertical Markets >

AGA-3 6.3 Download

AGA-3 6.3

License: Shareware $19.95
Downloads:
Publisher: NorCraft Software
File size: 4.06MB
OS: Windows XP
Date added: 2009-10-27
Homepage: http://www.NorCraft.com
Category: Business

AGA-3 6.3 Description

"Compute and measure orifice plates for gas and liquid."


Edit by : Programs AGA (AGA-3) and ISO ( ISO-5167) will size orifice Plates for given design conditions, find pressure drop for a given flow, or flow for a given pressure drop. The standards (AGA-3 ( API-2530: 1991) and ISO-5167: 2003) are originally designed for gas orifices. In these programs they are also used for liquid orifices.
The programs let you calculate the following orifice-types:
- Gas Orifice
- Liquid Orifice
- Restriction Orifice - Gas
- Restriction Orifice - Liquid
For gas-calculations you have to enter specific gas gravity, temperature and pressure. You can also give mole-fractions of N2, CO2 and H2S for sour gas calculations.
The AGA-8 Equation is used for calculating Z-Factor (compressibility factor) for natural gases, and the Redlich-Kwong equation of state for air and nitrogen.
For oil-calculations you have to enter specific oil gravity, temperature and pressure. It is also recommended to give molecular weight of oil. For water-calculations the input requirements are salinity, temperature, and pressure.
NOTE: It is assumed that all dissolved solids for water are expressed as equivalent sodium chloride concentration.
The results are an orifice specification sheet giving the necessary data for design of an orifice or evaluating an existing orifice.
The results will contain a few factors that you should know:
The velocity of approach factor is defined as:
Ev = 1/(Sqrt(1-Beta^4))
The flow coefficient, Alpha, is defined as:
Alpha = Ev * Cd
and orifice to pipe diameter ratio is given as:
Beta = OD/PID
API/ ANSI-2530 - 1991 (AGA Report No. 3) (AGA)
The basic flow equation is:
Qv = Fn*(Fc+Fsl)*Y1*Fpb*Ftb*Ftf*Fgr*Fpv*Sqrt(Pf1*hw)
where
Fn = Numeric conversion factor
Cd = Discharge coefficient = (Fc + Fsl)
Fc = Orifice calculation factor
Fsl= Slope factor
Y1 = Expansion factor based on upstream tap
Fpb= Pressure base factor, set to 1.0 (14.73 psia)
Ftb= Temperature base factor, set to 1.0 (60 deg F)
Ftf= Flowing.. you can free download AGA-3 6.3 now.

AGA-3 6.3 Keywords

AGA-3 6.3 Related Software

  • AGA-3
    Compute and measure orifice plates for gas and liquid.
  • AGA3
    Compute and measure orifice plates for gas and liquid.
  • ISO-5167 2003
    Compute and measure orifice plates for gas and liquid.
  • GOWProp
    This module lets you calculate gas and liquid physical properties.Gas calcula...
  • WatGas
    Calculate hydrates, water content, flowline inhibitor, CO2 solids.

AGA-3 6.3 Publisher's Software

    Software by Letter

    A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Others

    New Release Software